Leading brand of electrostatic precipitator for commercial kitchen ventilation.

Can a Ventless Hood Mobile Cooking Station Be Used for Smelly Foods?

Can a Ventless Hood Mobile Cooking Station Be Used for Smelly Foods?
Yes, a ventless hood mobile cooking station can be used for smelly foods, but it reduces odors rather than completely eliminating them. Its real-world performance depends on the filtration technology, cooking method, menu intensity, and how consistently the system is maintained.
2026 11 02
How to Properly Select and Configure Ecological Unit Components_008615019189367

How to Properly Select and Configure Ecological Unit Components_008615019189367

Ouyong
2026 10 29
What Percentage of Exhaust Air Should Be Replaced by Makeup Air?

In any ventilation system, air removed by an exhaust fan must be replaced. If it is not, the room will develop negative pressure. This can reduce exhaust performance, make doors hard to open, cause drafts, and pull unfiltered air into the workspace.
The replacement air is called makeup air.
2026 10 26
Periodic cleaning of kitchen exhaust ducts_008615019189367

Periodic cleaning of kitchen exhaust ducts_008615019189367
2026 10 21
Can a ductless hood handle the smoke from a high-volume commercial griddle?
A ductless hood can reduce grease and odor from a commercial griddle, but it is not automatically suitable for every high-volume setup. Whether it works depends on the cooking method, smoke level, filtration design, local fire codes, and how well the unit is maintained.
2026 10 19
Oil Mist Purifier ESP Electrostatic Field: Washable and reusable.ouyong008615019189367
Oil Mist Purifier ESP Electrostatic Field: Washable and reusable.
Ouyong:008615019189367
2026 10 14
How do I calculate the required CMH air flow for a CNC machine oil mist collector?

The most common simplified method for calculating the required airflow (CMH) for a CNC oil mist collector is: Internal Enclosure Volume × Air Changes Per Minute × 60. Measure the effective internal volume (V) of the machining chamber (Length × Width × Height in m³), ​​deducting the volume of major internal components (approx. 10–20%).
Select the air change rate (N) (changes/minute): Light mist/low-pressure coolant: 4–5
Standard cutting fluid: 5–6 (most common)
High-pressure coolant/heavy mist/smoke: 8–10

Calculation:
CMH = V × N × 60

Example: Effective volume 5.25 m³, N=6 → 5.25 × 6 × 60 = 1890 CMH. Add a 20–50% margin (to account for filter clogging and ducting losses). Opening method (for poor sealing):
Opening area (m²) × Capture velocity (0.5–1.0 m/s) × 3600 = CMH. Empirical reference: Small enclosed machine tools: 500–1200 CMH
Standard machining centers: 800–1500 CMH
Large/heavy-duty machines: 1500–2500+ CMH

For actual model selection, it is recommended to provide the machine model, chamber dimensions, and coolant pressure to the manufacturer for confirmation, while also considering ducting resistance and filter pressure drop.
2026 10 12
Troubleshooting Methods for Commercial Kitchen Exhaust Fans_WA008615019189367

Troubleshooting Methods for Commercial Kitchen Exhaust Fans

Ouyong WA:+8615019189367
2026 10 07
Self-cleaning electrostatic precipitator, Need to install a water heater?
Self-cleaning electrostatic precipitator ,Need to install a water heater?
2026 09 29
How to clean viscous grease from the composite media filter of a kitchen air purifier
How to clean viscous grease from the composite media filter of a kitchen air purifier
2026 08 28
Can a standard workshop dust collector capture cutting oil mist from machine tools?

Can a standard workshop dust collector capture cutting oil mist from machine tools
2026 08 21
Correct installation sequence for the filter screen and electric field of the ecological unit purification box

Correct installation sequence for the filter screen and electric field of the ecological unit purification box
2026 08 14
recommended for you

ABOUT RUIHE (DR. AIRE)

Dongguan Ruizhaohe Environmental Protection Equipment Co., Ltd

We are specializing in the design, production and after-sales service of fume purification

equipment and exhaust gas treatment equipment.

 


ONE-STOP AIR CLEANING MANAGEMENT SOLUTIONS


(1) - Commercial cooking fume odour management

(2) - Industrial exhaust management

(3) - CNC machines oil mist management

CONTACT US

Tel:86 - 0769 -  23667212    Fax:86 - 0769 - 27285034

 

E-mail:sales04@RUIHEetech.com

Adderss:Bajiaowo Industrial Zone, Wanjing District, DongguanCity, Guangdong Province, China

 

 

Follow Us & Like Us

Copyright © 2026 www.draire.net | Sitemap | Privacy Policy
Product Lives
Contact us
phone
whatsapp
Contact customer service
Contact us
phone
whatsapp
cancel
Customer service