Maintenance of commercial kitchen electrostatic smoke filters: avoiding misunderstandings is the key

Scientific maintenance is the key to ensure the long-term and efficient operation of  commercial kitchen electrostatic smoke filters, but many catering businesses have misunderstandings in daily maintenance, which not only cannot play a maintenance role, but may also damage the equipment. The following are four common misunderstandings and correct practices.

Misunderstandings of the maintenance of commercial kitchen electrostatic smoke filters 1

Misunderstanding 1: Use a high-pressure water gun to directly flush the inside of the commercial kitchen electrostatic smoke filter

For convenience, some businesses directly use a high-pressure water gun to flush the inside of the commercial kitchen electrostatic smoke filter, which will cause a short circuit in the circuit and rust of components. Especially for electrostatic purifiers, the core component, the dust collecting plate, is tightly connected to the circuit, and water may burn the power module.

Correct approach:

Disassemble the parts and clean them separately: remove the dust collecting plate, filter and other detachable parts, soak them in warm water and degreasing agent for 30 minutes, and then brush them;

Wipe the circuit part only: wipe the device housing and circuit interface with a dry cloth to avoid water.

Misunderstandings of the maintenance of commercial kitchen electrostatic smoke filters 2

Misunderstanding 2: Do not clean the filter/dust collecting plate if it is "visually clean"

The grease in the oil smoke is sticky, and some oil stains will adhere to the deep layer of the parts. It looks clean to the naked eye, but there are still residues. If it is not thoroughly cleaned for a long time, the purification efficiency will continue to decline and the equipment load will increase.

Correct approach:

Clean according to a fixed cycle: Regardless of whether the appearance is clean, it must be cleaned at a frequency of "once every 3 months for light oil smoke and once every 15-30 days for heavy oil smoke";

Check the cleaning effect: After cleaning, observe whether there is an oil film on the surface of the component to ensure that there is no residue.

Misunderstandings of the maintenance of commercial kitchen electrostatic smoke filters 3

Misunderstanding 3: Maintenance only focuses on purification components and ignores fans

The fan is the "power source" for the operation of the equipment, but it is often neglected for maintenance. The oil stains on the blades will cause unbalanced rotation, increase noise and energy consumption, and in severe cases, cause the motor to overheat.

Correct approach:

Check the fan blades every month: use a soft brush to remove the surface oil stains, and soak them with degreasing agent if necessary;

Lubricate the bearings regularly: add special lubricating oil to the fan bearings every 3 months to reduce wear.

Misunderstandings of the maintenance of commercial kitchen electrostatic smoke filters 4

Misunderstanding 4: Self-disassembly and repair after failure

When the equipment has problems such as abnormal noise and reduced purification effect, some merchants will disassemble and repair it by themselves, but if they do not understand the internal structure, they may damage the core components (such as the plates of the electrostatic field).

Correct approach:

Self-check for simple problems: If the filter is blocked, you can replace it by yourself, and if the power indicator light is not on, you can check whether the plug is loose;

For complex faults, please ask professionals: For problems involving core components such as circuits and motors, contact the manufacturer or professional maintenance personnel for processing.

Misunderstandings of the maintenance of commercial kitchen electrostatic smoke filters 5

Avoiding these maintenance misunderstandings can effectively extend the service life of commercial kitchen electrostatic smoke filter, reduce the occurrence of failures, and keep commercial kitchen electrostatic smoke filter in an efficient operating state at all times, providing continuous protection for the kitchen environment.

How can commercial kitchen electrostatic filters balance filtration efficiency and long-term stable operation?
next
recommended for you
no data
GET IN TOUCH WITH Us

ABOUT RUIHE (DR. AIRE)

Dongguan Ruizhaohe Environmental Protection Equipment Co., Ltd

We are specializing in the design, production and after-sales service of fume purification

equipment and exhaust gas treatment equipment.

 


ONE-STOP AIR CLEANING MANAGEMENT SOLUTIONS


(1) - Commercial cooking fume odour management

(2) - Industrial exhaust management

(3) - CNC machines oil mist management

CONTACT US

Tel:86 - 0769 -  23667212    Fax:86 - 0769 - 27285034

 

E-mail:sales04@RUIHEetech.com

Adderss:Bajiaowo Industrial Zone, Wanjing District, DongguanCity, Guangdong Province, China

 

 

Follow Us & Like Us

Copyright © 2025 www.draire.net | Sitemap Privacy Policy
Customer service
detect