Electric welding machine processing of smoke secondary voltage failure analysis and processing

Electric welding machine processing of smoke secondary voltage failure analysis and treatment welder smoke secondary voltage without secondary current, or abnormal small secondary current value. The cause of the problem: a, too much dust concentration in corona occlusion; b。 Yin, severe anode coating; c。 High pressure loop current meter measurement circuit breaker; d。 High voltage output and poor contact electric field; e. Ma table pointer stuck. Exclusion measures: a. Improve process flow, reduce flue gas dust concentration; b。 Strengthen the shaking, removal of dust; c。 Make the grounding resistance to achieve specified requirements; d。 Repair the circuit; E contact parts repair, make its good contact; 。 Repair milliammeter. Spark the cause of the problem: too much manhole door air leakage, moist air to enter; Boiler water leakage, insulator dirty. Ruled out measures: adopt corresponding measures to eliminate. Welding process of smoke dust collector efficiency is not high the cause of the problem: a. Pole spacing differ too much; b。 , uneven distribution of airflow distribution board wall ash; c。 Working condition of leakage rate, big change, increase the flue gas velocity, temperature drops, so that the dust load performance; d。 Mote than resistance is too high, and even generate electricity, the electric drive performance degradation, and make the deposit in the dirt on the electrode and slow, adhesion force is very big, the shaking hard to fall off; e. High voltage power supply is not stable, automatic voltage regulating system reduced sensitivity or malfunction, the actual low operating voltage; f。 In electric TuChen flue gas conditions do not conform to the original design conditions, working condition of change; G there has been a mechanical malfunction with the equipment, such as bad play function, etc. ; h。 Ash hopper choke plate, air bypass. Exclusion measures: a, adjust the spacing; b。 Remove plugging ash or replace distribution board; C, repair welding or blocked air leakage; d。 The flue gas conditioning ( Such as increasing humidity) , or adjust the working point; E, repair or replace the high voltage power supply; 。 According to the correction curve according to the actual condition to adjust the secondary voltage and current: 8 overhaul vibrating device, or appropriate increase the weight. h。 Check choke plate and do processing.

An increasing dependence on the use of electronic air cleaner hotel kitchen equipment video has made numerous changes in the kitchen cooker hood video industry over the past decades.

Being a performance leader means Dongguan Ruizhaohe Environmental Protection Equipment Co., Ltd. will achieve operational excellence, industry-leading customer satisfaction and superior financial performance.

The global market is estimated to reach a value of almost electrostatic filter project video in the next decade. have a robust position in the electrostatic air filter maintenance video market because of its proven high potency in commercial kitchen equipment video.

GET IN TOUCH WITH Us
recommended articles
Knowledge exhibition INFO CENTER
Island Style Range Hoods The Ideal Addition to Modern Kitchen Designs

When it comes to designing a modern kitchen, there are a few key elements that can truly make the space stand out.
Industrial workplaces are filled with machines that operate at high speeds, generating a high volume of oil mist and other types of particulate matter.
Activated Carbon Filters Removing Harmful Chemicals in the Air

Activated carbon filters have long been known to be effective in improving indoor air quality.
Activated Carbon Filters The Ideal Solution for Reducing Unpleasant Odors

Odors are a part of everyday life.
Activated Carbon Filters The Ultimate Solution for Eliminating Unpleasant Cooking Odors

Cooking can be such an enjoyable activity, where you can explore new flavors, dishes, and techniques.
Effective Odor Control with Activated Carbon Filters

Every household contains various odors that may be unpleasant or uninvited.
Maintaining Clean Air in Commercial Kitchens with State of the Art Electrostatic Precipitators

Running a kitchen is no easy task.
Electrostatic Precipitators The Best Defense Against Hazardous Particulate Matter in the Air

Air pollution is one of the greatest environmental concerns facing the human race today.
Island Style Range Hoods Innovating Kitchen Ventilation for Optimal Performance

Cooking can be a fun and exciting activity, but it is not without its challenges.
Reducing Environmental Impact with Industrial Electrostatic Precipitators

Introduction

Industrialization has revolutionized the world, but it also has left a heavy footprint on the environment.
no data

ABOUT RUIHE (DR. AIRE)

Dongguan Ruizhaohe Environmental Protection Equipment Co., Ltd

We are specializing in the design, production and after-sales service of fume purification

equipment and exhaust gas treatment equipment.

 


ONE-STOP AIR CLEANING MANAGEMENT SOLUTIONS


(1) - Commercial cooking fume odour management

(2) - Industrial exhaust management

(3) - CNC machines oil mist management

CONTACT US

Tel:86 - 0769 -  23667212    Fax:86 - 0769 - 27285034

 

E-mail:sales04@RUIHEetech.com

Adderss:Bajiaowo Industrial Zone, Wanjing District, DongguanCity, Guangdong Province, China

 

 

Follow Us & Like Us

Copyright © 2025 www.draire.net | Sitemap Privacy Policy
Customer service
detect